45KVA UPS
Online UPS & Solar UPS

For PCs, Servers, medical & research equipment, Industrial and special purpose machines

Solar MPPT based PCU/ OFF-Grid INVERTER
Frequency converter 60HZ / 400HZ

  • DSP technology, PFC UPS
  • 100% Indegenous, Industrial grade model
  • Regenerative load handling

  • Specialised in Online UPS for industrial application since 1998.
  • Indigenously designed in our art-of-state, full fledged in-house R&D.
  • Exported to Nigeria, Nepal, Malaysia & Philippines.

CERTIFICATES

arvi cerification

 

Arvi Systems & Controls Pvt Ltd Is one of the leading Bangalore based manufacturer and exporter of Online UPS & solar power solutions from 5KVA - 250KVA from 1998.

ARVI Systems & Controls Pvt. Ltd, Bangalore, is an ISO 9001:2015 certified company engaged in the manufacture, export and supply of UPS and other power management solutions since 1998. We at ARVI, offer customized and reliable solutions for all power related issues rather than offering readymade products. Solutions are offered based on...More

UPS OEM Factory

Awarded as the best in class 5KVA - 250KVA UPS manufacturer in Bangalore.

Get a Free Quote

Ask for 5KVA-250KVA UPS, and we will get back in matter of minutes.

Call Us on +91 98801 91720

* These fields are required.

Online UPS, Active shunt UPS 303 (IR,SR & CR), Solar GSS & PCU

Online UPS - 5KVA - 250KVA / 3Ø-3Ø

Technology
Industrial grade design with SNMP and remote monitoring. DSP model with galvanic isolation, Power Factor Correction model (PFC), VFI, power-conditioning, True Online with double conversion. Redundant with hot-standby, critical/non-critical load configuration and built-in static bypass.

Active shunt UPS - 5KVA - 250KVA

Technology
Mains synchronised, DSP technology. Zero-transfer time without double conversion losses, saves approximately 35-40% of elctricity. Industrial grade, highly rugged design; can handle high crest factor loads. Used for process industry, CNC & laser processing etc.

Solar UPS / Hybrid inverter / PCU / GSS - 5KVA - 250KVA in 3Ø-3Ø;

Technology
Available in (GSS) Grid shared solar UPS and hybrid solar PCU/inverter. MPPT based technology, using DSP. IGBT based industrial model. Can also work without battery and also does not need mains reference as compared to On-grid/grid export solar inverter.

Applications
  • Process automation
  • CT & MRI scanners
  • Offset machines
  • Industrial machineries
  • Laser cutting & bending machines
  • Vertical milling CNC
  • Wire cut EDMs, etc

Downloads

Online UPS


PFC 101


PFC 301


PFC 303


Active shunt


ASU - IG


Glider - 303


Solar UPS


Solar PCU


Solar GSS


MPPT

Buying Tips
Tips for buyer of Power conditioning equipment.

Quality power is the prime infrastructure of any business-process and a basic need of any successful sustaining operations, which is seldom given the importance that it requires. Due importance and budget is allotted for procurement of capital equipment but minimum effort is often put on providing an environment for it to function to the optimum; quality power being the foremost of it.

The below points are worth considering while buying power conditioners.

Basic objective of the purchase.

A power conditioner like a stabilizer and UPS are needed where power conditioning is the prime objective. Due importance is to be given to ensure the output power quality before glancing at the additional features. The sales documents focus more on features and not on the quality of the output power-which is fed to your equipment.

Second priority is to be given for human safety and equipment protection.

Once the above criteria are fulfilled then look for the required features.

Cost of ownership and Serviceability / life of the product.

A decision maker loves to bargain not only during purchase but also during signing service contracts with the service provider. Hence, make sure you buy a product, which can be serviced by another competent agency, or else might end up becoming puppets in their hands having bought proprietary serviceable equipment.

The other easy option is to sign a contract with the supplier for 10 years of spares availability, or 7-year warranty or AMC offer.

The vendors trap some of the users by offering very low prices with big features but with poor quality of output power and which are not serviceable by third party. The user is forced to accept the terms of the service provider as he has no option of comparing the quotes and these products offer life of not more than 5 years. Since this responsibility lies with the facility managers, the purchase team neglects this.

A purchase of a product is completed only on the day of expiry of warranty or completion of the liability period.

Hence, while purchasing smart decision makers find it meaningful to evaluate the following points before they take a decision.

Self-destructive negotiation.

Negotiation if it is win-win has mutually beneficial effects, however win-lose negotiation is often lose-lose situation, neither of them win at the end. Often it is better to evaluate the pulse of the service provider to find out his desperateness in closing the sale; often associated with agreeing to huge discounts and budging to all the terms of the customer (matching L1 price). He is more likely to do the same with every customer and is unlikely to last long to provide quality service to your product.

Cost comparison as per commercial offer can lead to wrong results since the hidden costs are not calculated. Cost per year (CPY) is the right way forward to calculate the real cost. If a product is purchased at a low cost, but has a life of just few years, would not justify the huge investment. Generally, a life of 10 years is desirable.

CPY = CII+ CAMAC

Cost of initial investment (CII)-All-inclusive price with onsite support inclusive of all accessories, including the cost of investment like conditioned environment, isolation transformer etc, sometimes is recommended as mandatory by the supplier. (Eg: Air conditioner).

Cost of AMC charges (CAMAC)- Maintenance cost after the expiry of warranty period.

Expected life of equipment (ELE)-Generally governed by the manufacture’s policy and design.

The purchase cost is to be treated as a down payment towards an installment purchase.

View More Range of Products

OEM  Manufaturer

OEM
Manufaturer

Tough built, & Long life Design

Tough built, & Long life
Design

Green Power Initiative

Green Power
Initiative

OEM  Manufaturer
Awarded as the Best In-House R&D among Indian UPS manufacturers by SoftDisk 2018-19

  • Manufactured in our state-of-art manufacturing facility in Bangalore.
  • Exported to Nigeria & Dubai Over 50000 installation.
  • Industrial application-specific Products & solutions from past 19 year.

5KVA - 250KVA UPS Customer Reviews

FAQ - Frequently Asked Questions

A1. Depending upon the type of application and need you can opt between a backup power or power-conditioning UPS. Backup UPS saves power and electricity bills in comparison to double conversion Online UPS and if the application is not critical and the requirement is only for process continuity then a Back up UPS would suffice.
If the load is very sensitive and of critical application the need is of Uninterupted Quality Power rather than uninterupted power. This is because the life of the connected equipment is directly propotional to the quality of the power and the equipment/ process uptime can be greatly enhanced or optimised using Power-Conditioning Online UPS.
A2. Choosing among the different options and technology advantages offered by different vendors can often be very tricky indeed. Should I for an Industrial grade UPS, UPS with isolation transformer, DSP technology, PFC technology; depends on the type of load electrical and environmental conditions under which the UPS is required to operate.
If the load is Industrial, it is a better idea to opt for UPS for Industrial application or Industrial grade UPS. If there is a backup generator, it is recommended to opt for PFC UPS. DSP technology enhances the protects and power quality. Galvanic isolation is required at the output if the premium grade, high quality power with comprehensive power protection is the need.
A3. Load study reveals the load PF, input harmonic current, surge/crest etc that will determine the buffer capacity required to handle the existing load and add up the spare capacity for the future expansion in the next one year to arrive at the capacity of UPS.
A4. Technical jargons like THDi, transient recovery, input voltage window are to be very closely considered and compared between the offers. SNMP or GSM for remote power monitoring is a good feature to opt for. Crest factor of UPS recveals its capacity to handle surge lodas without derating. The output voltage regulation (Phase-Neutral) during imbalanced loading is also a critical parameter to consider.
A5. Although you can use a conventional commercial grade UPS for Laser cutting machine, considering the cost of investment and loss of downtime, its a better to opt for Industrial Grade UPS which are ideally designed for tough loads.
A6. Yes you can by opting for suitable UPS, by getting a site and load study done.
A7. Battery capacity should be calculated with multiple power interuptions in mind, the discharge current is another factor that needs to be considered while calculating the AH for better life of battery. A tight claculation leads to premature failure of batteries and can lead to process downtime.
A8. If the operator / user is very near the UPS and is connected near the load, remote power monitoring may not be required as long as the application is not very critical. However remote power monitoring enhances power availability and avoids ungraceful shutdown of connected loads.
A9. Load sharing paralell redundant UPS with N+1 offers the advantage of upgrading the UPS capacity and also redundancy. PRS with N+1 is the best option if dynamic load expansion is a requirement especially with IT loads. However if the loads are Industrial in nature and redundancy is a necessity, the serial redundant hot standby is a better option in handling shortcircuits than PRS.
A10. Instead of manually bypassing the load to mains during an evantuality of UPS shutdown, a static switch(Thyristors back-back) automatically bypasses the load without interuption and ensures uninterpted power from mains - this is called static bypass.
A11. Depending upon the discharge current, type of cyclic discharge, opearting temeperature, backup required etc a SMF or tubular batteries are opted.
A12. Most often the solution for a particular problem becomes a source of another problem. This is true even in the case of Online UPS. The UPS pollutes the input power source by injecting harmonic current back into it. Input Power factor correction uses advanced electronic circuitry integrating high performance IGBTs. These reduces the running cost in terms of electricity bill and prevent the overrating of electrical wires, reduce reflected harmonies back to the source and provides better utility of grid/generator power; the UPS is guaranteed to protect the upstream sensitive equipments. The UPS is utility friendly and generator compatible.
A13. Smart chargers with temperature compensation, constant current-constant voltage with intelligent time bound boost and float voltage configuration using a DSP is the best charger for optimum battery life. Built-in battey charge equivaliser is also highly benefecial.
A14. Yes the ecomode option in Online UPS does save electricity, but why opt for Online UPS if the loads can handle the voltage variations during mains. Alternatively a servo-controlled voltage stabiliser with a backup UPS would be a better option for process continuity.
A15. Transient response of a UPS necessarily means the time required by the UPS to correct the voltage within the permissable bandwidth to respond to sudden increase or decrease of load.
A16. Indian UPS manufacturers consider the input voltage, environmental and power condition which is considered to be harsh as per International parameters and hence these UPS lasts longer in Indian power conditions. Wheras imported UPS are designed considering International power conditions and hence are prone to failure especially under polluted power condition.
A17. Capability to handle large inrush load current, ability to handle low PF and high load current harmonics are very important for a UPS in Industrial environment. Due importance is to be given to creepage in PCB design, use of connectors and transformer design. UPS for Industrial application should be capable of handling back feed of regenerative loads.
A18. Yes definitely the UPS can be customised to handle any type of motor; The factors to be considered are (a) What kind of motor is it? Is it DOL, line motor or motor with VFD etc. The initial starting current, running current, PF, current THDi, type of motor operation etc .
A19. Is it a power-conditioning Online UPS or Is it just voltage stabilising Online UPS is the first point to be considered, secondly Is it a commercial UPS (Normal UPS that is used for all general application) or a UPS for Industrial application? Can it handle regenerative load? These are some of the points to be considered before deciding a UPS for CNC machine.
A20. Double conversion losses amount to 35%-40% of increased electricity bill and using an Active Shunt UPS is the only solutionto the mentioned problem. Active Shunt UPS ensures seamless transfer(Zero tranfer time) during generator chang-over without double conversion losses saving 3%-4% of electricity bill in comparison.

About Us

ARVI Systems & Controls Pvt. Ltd, Bangalore, is an ISO 9001:2015 certified company engaged in the manufacture, export and supply of UPS and other power management solutions since 1998. We at ARVI, offer customized and reliable solutions for all power related issues rather than offering readymade products. Solutions are offered based on application specific requirement, after an analysis from our team of power management experts.

With an expertise of over 22 years, and with more than 30,000 installations across the country and abroad on various types of application, we have an accurate knowledge of the power requirement for respective applications and our team is known for offering the best solution. We have a strong in-house R&D team and all the products are designed and manufactured for harsh Indian power conditions with stringent process control ensuring highly reliable and quality products; always keeping in pace with the advanced technology incorporated.

Our products are designed, built and tested to perform in the most difficult situations in our state-of-the -art manufacturing facility and are certified as per IEC-62040-1,2,3 & CE marking. Our high standards of manufacturing process, quality, reliability and after sales has been evaluated and certified by leading testing agencies and consultants.

As an approved vendor by BEL, Accenture, Honewell, L&T etc we are sure to exceed your expectation of quality and support. A penchant for exceptional quality and customer satisfaction has been embedded in our infrastructure and is the reason for our success.

We have won the prestigious awards for best after sales service and for best in product category in 1PH-PH, 3PH-1PH, 3PH-3PH models by the SD awards for 9TH consecutive time.

ARVI has a full fledged in-house R & D and all the products manufactured are designed in house indigenously.

Our Promise

We promise to use our experience and expertise to the best of our capabilities to bring out need based power solutions and to redeem our customers of all power related interruptions, by offering them premium quality products and solutions.

We shall work with highest ethical values adding value to life and contributing our part of social accountability & serving the society which has empowered us to do so to which we are deeply indepted to.

We promise to live up to their trust by serving them to their delight.

Contact Us

INDIA - CORPORATE OFFICE / WORKS

ARVI Systems & Controls Pvt. Ltd
#80/A2, 1st main, 3rd cross,
2nd stage, Industrial suburb,
Yeshwanthpur,
Bangalore 560022.

Contact person: Mr.Santosh Risbood(Senior sales manager)

Mob: +91-9880191720 (calling & whats app)
Tel: 91-80-41558550 (5 lines), 91-80-23470657/8
Email: sales@arviups.com, enquiry@arviups.com

AT NIGERIA

Standard Eletro-Medical Equipment Company(SEMED)
First Floor, Last Warehouse
Sunrise Industrial Complex, Beside S & M Nigeria Ltd
Dawaki Express way
Abuja, Nigeria
Office Line +234 817 9401 627
Mobile Phone +234 803 9699 730
Email : anthony.ele@semednigeria.com
Visit us at www.semednigeria.com
Contact person : E.E. Anthony (Country director)