Get a Free Quote
Please send us your enquiry and we will get back to you in a matter of minutes.
Call Us on +91 98801 91720
UPS OEM Factory
Awarded as the best in class 10KVA - 400KVA UPS manufacturer in Bangalore, India
UPS factory for OEMs
Arvi supplies UPS in your brand name (OEM / the UPS supplier brand name).
Arvi becomes an extension of your organization, serving as an outsourced factory. OEMs can focus on branding, sales, and service, while Arvi takes care of the heavy lifting: R&D, product quality, new feature development, and manufacturing challenges. The result? You enjoy the benefits of in-house production without the associated overheads, ensuring the product offers the same value as if it were manufactured by you.
Truly Indian with 75-80% local / Indian content
- with export compliance features

At a time when self-reliance is driving India’s industrial backbone, Arvi stands out with a 75–80% locally designed and manufactured product line. This indigenous approach not only ensures robust quality but also strengthens India’s vision of “Make in India.”
Many so called manufacturers import UPS as semi knocked down kits and reassemble it in India under Make in India initiative; but the UPS design and its sub assembly are not Indian. They are designed for general requirement and are mass produced and sold as "box selling" and hence the life of these UPS are typically 5-6years in the harsh environment of India.
State-of-art manufacturing facility with Strong end to end in-house R&D team
Manufacturer and exporter of industrial grade UPS for OEMs since 1998.
Awarded as the best in-house R&D among Indian UPS manufacturers
- 27+ years of industry expertise
- 1,26,000+ successful installations
- Power Factor Corrected, Parallel redundant UPS
- SNMP, MODBUS-BMS communication interface
- Regenerative load handling for 5-axis milling machines
- Indigenous design
- Easy to service single DSP card
- Rugged, long-life design.
- Enjoy 100% after sales service revenues
- Prompt & ex-stock delivery
- 10years of unconditional spares support.
Enhance your Brand image - By making and honoring comittments.
Through a "ONE TEAM" approach and prompt back-to-back support, Arvi ensures your delivery and service commitments to end customers are met.
By consistently honoring commitments in
- On-time delivery
- Spares availability
- Engineer training, Arvi strengthens and enhances your brand image.
Unmatched Support, Guaranteed
Arvi promises 10 years of unconditional spares support—regardless of business continuity or sales volumes. This long-term commitment assures OEMs and their end customers of uninterrupted service and peace of mind.
Our Product Range
Online UPS with load sharing, parallel redundancy for critical applications
Applications : Data centre, servers, research, pharma processing, hospital OT applications.
Capacity : 10KVA - 400KVA
Enquire nowPFC-ITR303

Industrial grade Online UPS customised for laser cutting machines.
Capacity : 10KVA - 400KVA
Enquire nowPFC-XR303

PFC-IG303

Online UPS specially designed for CT, MRI, PET scanners and linear accelerator.
Capacity : 10KVA - 400KVA
Enquire nowPFC-iPL303

High efficiency, Green converter - Industrial grade UPS with 0.99PF and less than 3% THDi.
Applications : IT and industrial automated processing
Capacity : 10KVA - 400KVA
Enquire nowHG-303 12YPL Gcon

Online UPS for production printers, Rotogravure and offset printers etc
Capacity : 10KVA - 400KVA
Enquire nowPFC-XPS303

Regenerative load handling Online UPS
Applications : VMC, HMC, grinding machines and such regenerative loads
Capacity : 10KVA - 400KVA
Enquire nowPFC-IG303RL

Uninterrupted Process Continuity during generator change-over, Backup UPS to ensure seamless transfer of industrial loads during generator change-over.
Capacity : 10KVA - 400KVA
Enquire nowGLIDER 303

Active shunt backup UPS with zero change-over, with built-in mains voltage stabiliser; saves approximately 30-35% electricity bills in comparison to Online UPS.
Applications : Schools and colleages, home ofiice, lighting applications, residential use
Capacity : 5KVA - 12KVA
Enquire nowASU-101

Active shunt backup UPS with zero change-over; saves approximately 30-35% electricity bills in comparison to Online UPS.
Applications : Villas, apartment, industrial application, Schools and colleages, lighting applications, residential use
Capacity : 10KVA - 400KVA
Enquire nowASU-303

ASSU

PFC101

Online UPS, 10KVA - 50KVA, 3Ø-1Ø
Applications : IT and industrial loads
Capacity : 10KVA - 50KVA
Enquire nowPFC 301

60Hz static frequency convertor with 50Hz input
Applications : Imported equipment needing 60Hz power supply, industrial applications
Capacity : 2KVA - 200KVA
Enquire nowSFC 50FC60

400Hz static frequency for aerospace application
Applications : Testing, simulation etc
Capacity : 5KVA - 200KVA
Enquire nowSFC FC400

50Hz static frequency converter with 60Hz input
Applications : Equipment that works on 60Hz input power supply
Capacity : 5KVA - 200KVA
Enquire nowSFC 60FC50

About Us
ARVI Systems & Controls Pvt. Ltd, Bangalore, is an ISO 9001:2015 certified company engaged in the manufacture, export and supply of UPS and other power management solutions from 10KVA - 400KVA since 1998. We at ARVI, offer customized and reliable solutions for all power related issues along with offering readymade products. Solutions are offered based on application-specific requirements, after an analysis from our team of power management experts.
With an expertise of over 27 years, and with more than 1,26,000 installations across the country and abroad on various types of application, we have an accurate knowledge of the power requirement for respective applications and our team is known for offering the best solution More
Online UPS, Active shunt UPS 303 (IR,SR & CR), Solar GSS & PCU
Online UPS - 60KVA - 200KVA / 3Ø-3Ø
Technology
Industrial grade design with SNMP and remote monitoring. DSP model with galvanic isolation, Power Factor Correction model (PFC), VFI, power-conditioning, True Online with double conversion. Redundant with hot-standby, critical/non-critical load configuration and built-in static bypass.
Active shunt UPS - 60KVA - 200KVA
Technology
Mains synchronised, DSP technology. Zero-transfer time without double conversion losses, saves approximately 35-40% of elctricity. Industrial grade, highly rugged design; can handle high crest factor loads. Used for process industry, CNC & laser processing etc.
Solar UPS / Hybrid inverter / PCU / GSS - 60KVA - 200KVA in 3Ø-3Ø;
Technology
Available in (GSS) Grid shared solar UPS and hybrid solar PCU/inverter. MPPT based technology, using DSP. IGBT based industrial model. Can also work without battery and also does not need mains reference as compared to On-grid/grid export solar inverter.
Applications
- Process automation
- CT & MRI scanners
- Offset machines
- Industrial machineries
- Laser cutting & bending machines
- Vertical milling CNC
- Wire cut EDMs, etc
Technical Specification
Capacity | ||
---|---|---|
MODEL | PFC 303, PFC Series Online UPS | |
TECHNOLOGY | DSP based double conversion Online UPS using IGBT. | |
RATING | 100KVA | |
DC BUS | 360VDC | |
INPUT | ||
Input Voltage | 415VAC, 3Ø & N | |
Input Voltage Window | 330VAC - 470VAC | |
Input Frequency | 50Hz ± 10% | |
Input PFC @ 100 % Load | > 0.95 | |
Power walk in | With Soft start | |
RECTIFIER | ||
Type | IGBT based full bridge | |
Voltage Regulation | ( ± ) 1% | |
Ripple Voltage | < 2% | |
Converter Protection | Advanced Electronic Protection for device safety backed up with MCB's/ MCCBs & fast acting fuses. | |
INVERTER | ||
Inverter Type | IGBT based MPWM with instantaneous Sinewave Control | |
Power Factor | 0.8 lag | |
Nominal Voltage | 400VAC, 3Ø- 3Ø |230VAC, 1Ø- Neutral | |
Regulation | Balanced Load | ( ± ) 1% |
Unbalanced Load | ( ± ) 1% | |
Unbalanced Load Phase Shift | 120⁰± 0.5⁰ | |
Frequency | 50 Hz ± 0.1Hz | |
Waveform | True Sinewave | |
Total Harmonic Distortion | Linear Load | < 3% |
Non Linear Load | < 6% | |
Transient Response | Remains within +/- 5% & recover to normal within 20 msec | |
Over Load Capacity | 100% | Continuous |
125% | 1 Minutes | |
150% | 5 Seconds | |
Crest Factor | 3:1 | |
Mode of Operation | Designed for Continuous operation | |
ISOLATION | True Online with complete galvanic isolation. | |
Inverter Protection | Advanced Electronic Protection for device safety backed up with MCB's/ MCCBs & fast acting fuses, high speed pulse by pulse electronic device protection, over voltage / under voltage protection, Electronic over current trip. | |
BYPASS | ||
Manual Bypass | Provided | |
Static bypass(Optional) | Optional | |
EFFICIENCY | ||
Overall Efficiency on typical full load at site (80%) | > 90% | |
Charger | CCCV | |
ALARMS | ||
Input / Low / Fail | ||
Output Overload | ||
Over Temperature | ||
Battery low | ||
LED Indications (Single LED with multi function ) | ||
• Mains on | ||
• UPS On | ||
• Battery Low | ||
• Overload | ||
• UPS Trip | ||
User Friendly LCD Display shows the following parameters | ||
• Input Voltage | ||
• Output Voltage | ||
• Load Current | ||
• Output Frequency | ||
• Input frequency | ||
• Temperature | ||
• UPS On load on Battery | ||
• UPS On load on Mains | ||
• Battery Low warning and battery low trip | ||
• Over temperature warning and high tempature (trip) | ||
• Battery Voltage | ||
Optional features | GSM, SNMP for remote access, Static by pass for hot stand-by configuration. | |
PROTECTIONS | ||
PROTECTING THE LOAD | ||
Output Under Voltage | Protects the load and its components from premature failure. | |
Output Over Voltage | ||
Output Single Phase prevention | Protects the connected three phase loads & its components from premature failure. | |
Output short circuit with pulse by pulse current limit up to 200μ secs. Protects 300% for 15msecs, 500% for 5msec & 1000% for 1.5msec of the rated current | Protects against false tripping & complete shutdown in case of surge power drawn by the load (non linear loads) | |
Neutral drift | Galvanic isolation provides complete isolation between output neutral and Input & the the output is fully protected against neutral drifts, voltage avalanches like lighting & input harmonics commonly found in the input side. | |
Neutral failure | ||
Lightning | ||
EMI & Harmonics in the input neutral | ||
'High voltage transient protection & Electrostatic discharge protection as per IEC 62040-2 | ||
PROTECTING THE UPS | ||
Input MCCB/MCB | Protects the input from very large current caused by short circuit or due to a damaged internal component and avoids further damage to the equipment. | |
Input Under Voltage / Over Voltage | Prevents damage of components in the input sensing & the converter devices. | |
Rectifier Over Voltage | Prevents damage to the inverter & the charger components. | |
Single phase prevention | Prevents damages to the components in the input & converter. | |
Over Temperature Protection | Protects the Inverter, converter and switching devices against premature failure. | |
Battery Low protection | ||
Over Load protection | Protects the Inverter components against premature failure. | |
Short circuit protection | ||
High voltage transient protection & Electrostatic discharge protection as per IEC 62040-2 | Prevents damage of components in the input sensing & the converter devices. | |
External Magnetic field Protection | Protects against external power frequency magnetic field. | |
ENVIRONMENTAL | ||
Acoustic Noise level | <65db @ 1.5 meter | |
Ambient Temperature | 0 to 40 Deg C | |
Storage Temperature | -10 to 70 Deg C | |
Humidity | Up to 95% RH Non condensing | |
Altitude | < 3000 Feet above sea level (without derating) | |
Extreme climatic conditions | AC Environment is required if the temperature goes beyond the normal operating temperature (0-40 deg C) | |
PHYSICAL | ||
Enclosure Protection Grade | IP - 20 | |
Cooling | Forced Air | |
Cable Entry | Front side bottom | |
Dimension | D 1240 mm * W 690 mm * L 1310 mm Weight 710 Kg | |
Specifications are indicative to our standard models and are subject to change without notice. | ||
Downloads
Buying Tips
Tips for buyer of Power conditioning equipment.
Quality power is the prime infrastructure of any business-process and a basic need of any successful sustaining operations, which is seldom given the importance that it requires. Due importance and budget is allotted for procurement of capital equipment but minimum effort is often put on providing an environment for it to function to the optimum; quality power being the foremost of it.
The below points are worth considering while buying power conditioners.
Basic objective of the purchase.
A power conditioner like a stabilizer and UPS are needed where power conditioning is the prime objective. Due importance is to be given to ensure the output power quality before glancing at the additional features. The sales documents focus more on features and not on the quality of the output power-which is fed to your equipment.
Second priority is to be given for human safety and equipment protection.
Once the above criteria are fulfilled then look for the required features.
Cost of ownership and Serviceability / life of the product.
A decision maker loves to bargain not only during purchase but also during signing service contracts with the service provider. Hence, make sure you buy a product, which can be serviced by another competent agency, or else might end up becoming puppets in their hands having bought proprietary serviceable equipment.
The other easy option is to sign a contract with the supplier for 10 years of spares availability, or 7-year warranty or AMC offer.
The vendors trap some of the users by offering very low prices with big features but with poor quality of output power and which are not serviceable by third party. The user is forced to accept the terms of the service provider as he has no option of comparing the quotes and these products offer life of not more than 5 years. Since this responsibility lies with the facility managers, the purchase team neglects this.
A purchase of a product is completed only on the day of expiry of warranty or completion of the liability period.
Hence, while purchasing smart decision makers find it meaningful to evaluate the following points before they take a decision.
Self-destructive negotiation.
Negotiation if it is win-win has mutually beneficial effects, however win-lose negotiation is often lose-lose situation, neither of them win at the end. Often it is better to evaluate the pulse of the service provider to find out his desperateness in closing the sale; often associated with agreeing to huge discounts and budging to all the terms of the customer (matching L1 price). He is more likely to do the same with every customer and is unlikely to last long to provide quality service to your product.
Cost comparison as per commercial offer can lead to wrong results since the hidden costs are not calculated. Cost per year (CPY) is the right way forward to calculate the real cost. If a product is purchased at a low cost, but has a life of just few years, would not justify the huge investment. Generally, a life of 10 years is desirable.
CPY = CII+ CAMAC
Cost of initial investment (CII)-All-inclusive price with onsite support inclusive of all accessories, including the cost of investment like conditioned environment, isolation transformer etc, sometimes is recommended as mandatory by the supplier. (Eg: Air conditioner).
Cost of AMC charges (CAMAC)- Maintenance cost after the expiry of warranty period.
Expected life of equipment (ELE)-Generally governed by the manufacture’s policy and design.
The purchase cost is to be treated as a down payment towards an installment purchase.
OEM
Manufaturer
Tough built, & Long life
Design
Green Power
Initiative
Awarded as the Best In-House R&D among Indian UPS manufacturers by SoftDisk 2018-19
- Manufactured in our state-of-art manufacturing facility in Bangalore.
- Exported to Dubai, Nigeria, Nepal, Malaysia & Philippines Over 1,00,000 installation.
- Industrial application-specific Products & solutions from past 27 year.
FAQ - Frequently Asked Questions
About Us
ARVI Systems & Controls Pvt. Ltd, Bangalore, is an ISO 9001:2015 certified company engaged in the manufacture, export and supply of UPS and other power management solutions from 10KVA - 400KVA since 1998. We at ARVI, offer customized and reliable solutions for all power related issues along with offering readymade products. Solutions are offered based on application-specific requirements, after an analysis from our team of power management experts.
With an expertise of over 27 years, and with more than 1,26,000 installations across the country and abroad on various types of application, we have an accurate knowledge of the power requirement for respective applications and our team is known for offering the best solution. We have a strong in-house R&D team and all the products are designed and manufactured for harsh Indian power conditions with stringent process control ensuring highly reliable and quality products; always keeping in pace with the advanced technology incorporated. We have representation in Nigeria for the past 13years supplying Online UPS specially designed for CT, MRI and X-ray machines.
Our products are designed, built and tested to perform in the most difficult situations in our state-of-the-art manufacturing facility and are certified as per IEC-62040-1,2,3 & CE marking. Our high standards of manufacturing process, quality, reliability and after sales has been evaluated and certified by leading testing agencies and consultants. We are specialised in designing and manufacturing Power-conditioning, Industrial Grade UPS for process industry, CNC and Laser machines with regenerative energy.
As an approved vendor by BEL, Accenture, Honewell, L&T etc we are sure to exceed your expectation of quality and support. A penchant for exceptional quality and customer satisfaction has been embedded in our infrastructure and is the reason for our success.
We have won the prestigious awards for best after sales service and for best in product category in 1PH-PH, 3PH-1PH, 3PH-3PH models by the SD awards for 9th consecutive time. ARVI in-house R & D was awarded as the Best R&D among the Indian manufacturers for the year 2019 by Softdisk.
Our Promise
We promise to use our experience and expertise to the best of our capabilities to bring out need based power solutions and to redeem our customers of all power related interruptions, by offering them premium quality products and solutions.
We shall work with highest ethical values adding value to life and contributing our part of social accountability & serving the society which has empowered us to do so to which we are deeply indebted to. We promise to live up to their trust by serving them to their delight.
Contact Us
ARVI Systems & Controls Pvt. Ltd
#80/A2, 1st main, 3rd cross,
2nd stage, Industrial suburb,
Yeshwanthpur,
Bangalore 560022.
Contact person: Mr.Santosh Risbood (GM Sales)
Mob: +91-9880191720 (calling & whats app)
Tel: 91-80-23470657/8
Email: sales@arviups.com, enquiry@arviups.com
Standard Eletro-Medical Equipment Company(SEMED)
First Floor, Last Warehouse
Sunrise Industrial Complex, Beside S & M Nigeria Ltd
Dawaki Express way
Abuja, Nigeria
Office Line +234 817 9401 627
Mobile Phone +234 803 9699 730
Email : anthony.ele@semednigeria.com
Visit us at www.semednigeria.com
Contact person : E.E. Anthony (Country director)